Oil Karl Fischer Trace Moisture Analyzer
BDT 0/-
Product Details
Brand: Huazheng
Model: HZKF-2
Oil Karl Fischer Trace Moisture Analyser The trace moisture analyzer of our company meets the requirements of GB/T 7600, SH/T 0255, GB/T6283, SH/T 0246 and other method standards. The Karl Fischer (Coulomb) method was adopted to determine the content of trace amounts of moisture in liquids of...
Application Areas
Transformer & insulating oil testing - trace moisture analysis for dielectric oil quality control
Petroleum & petrochemical labs - moisture in oils, solvents, and hydrocarbon products
Electric power utilities - oil condition monitoring and preventive maintenance
Pharmaceutical & chemical QC - moisture in raw materials, intermediates, and finished products
Environmental & pesticide labs - trace water in organic liquids and formulations
Research laboratories - fast, accurate moisture determination across diverse liquid matrices
| Functions and Features |
The instrument incorporates a powerful next-generation processor and new peripheral circuits, offering excellent low power consumption. The measuring electrode signal serves as the criterion for determining the endpoint of electrolysis. Its stability and accuracy are key factors affecting measurement precision. Through the use of advanced devices and methods, precise detection of the measuring electrode signal has been achieved. Further understanding of reagent characteristics has led to the development of a new software compensation correction algorithm, which improves measurement accuracy. A Chinese/English character graphic LCD provides an intuitive and user-friendly display interface. |
| Main functions: |
●Adopting high-resolution color 480×272 dot matrix color touchscreen LCD, English man-machine dialog interface; ●The use of switching constant current source electrolysis circuit (patented technology) to reduce the power consumption of the instrument; ● High-precision measurement electrode signal generation and detection circuits make the judgment of the electrolysis end point fast and accurate, and have strong anti-interference ability; ● Two methods are used to correct the measurement results: reagent blanking current compensation and equilibrium point drift compensation; ● Built-in 9 kinds of calculation formulas, which can meet the calculation of moisture content under different measurement conditions; ● One injection can be converted into mg/L, ppm, mg/kg, %, % to reduce the number of measurements and reagent consumption, and the moisture content conversion unit can also be specified; ● Adjustment of samples volume, mass and density adjustment can be carried out during or after the test; ● 9-speed stirring speed adjustment; 9-speed electrolysis gain adjustment; ● Automatic detection and recording of measuring electrode open-circuit fault and short-circuit fault; ● Automatic storage of historical records with time stamps; ● Reserve RS232 and RS485 ports to communicate with the computer |
| Accuracy |
3 μg~1 mg: ±3 μg Above 1 mg: 0.3% (excluding injection error) |
| Measuring Range | 3 μg~100 mg |
| Resolution | 0.1 μg |
| Electrolytic Current | 0~400 mA |
| Maximum Electrolytic Speed | 40 μg/s |
| Power Supply Voltage | AC 220V ± 20% |
| Standby Power Consumption | 5 W |
| Ambient Temperature | 5~40 ℃ |
| Ambient Humidity | <80% |
| Overall Dimension | 320 × 240 × 200 mm |
| Weight | 4.5 kg |
The HZKF-2 karl fischer trace moisture analyzer of huazheng electric meets the requirements of GB/T 7600, SH/T 0255, GB/T6283, SH/T 0246 and other method standards. The Karl Fischer (Coulomb) method was adopted to determine the content of trace amounts of moisture in liquids of different properties. The trace moisture analyzer has the advantages of high measurement accuracy, fast speed, stable and reliable measurement data, and is widely used in petroleum, chemical, electric power, environmental protection, medicine and other
departments. It can quickly determine the moisture content of alcohols, oils, lipids, ethers, esters, acids, alkanes, benzenes, amines, organic solvents, pesticides, phenols, pharmaceutical raw materials and other chemical, petroleum, pharmaceutical, pesticide and other products.
Application Areas
Transformer & insulating oil testing - trace moisture analysis for dielectric oil quality control
Petroleum & petrochemical labs - moisture in oils, solvents, and hydrocarbon products
Electric power utilities - oil condition monitoring and preventive maintenance
Pharmaceutical & chemical QC - moisture in raw materials, intermediates, and finished products
Environmental & pesticide labs - trace water in organic liquids and formulations
Research laboratories - fast, accurate moisture determination across diverse liquid matrices
Functions and Features
The instrument incorporates a powerful next-generation processor and new peripheral circuits, offering excellent low power consumption.
The measuring electrode signal serves as the criterion for determining the endpoint of electrolysis. Its stability and accuracy are key factors affecting measurement precision. Through the use of advanced devices and methods, precise detection of the measuring electrode signal has been achieved.
Further understanding of reagent characteristics has led to the development of a new software compensation correction algorithm, which improves measurement accuracy.
A Chinese/English character graphic LCD provides an intuitive and user-friendly display interface.
Main functions:
●Adopting high-resolution color 480×272 dot matrix color touchscreen LCD, English man-machine dialog interface;
●The use of switching constant current source electrolysis circuit (patented technology) to reduce the power consumption of the instrument;
● High-precision measurement electrode signal generation and detection circuits make the judgment of the electrolysis end point fast and accurate, and have strong anti-interference ability;
● Two methods are used to correct the measurement results: reagent blanking current compensation and equilibrium point drift compensation;
● Built-in 9 kinds of calculation formulas, which can meet the calculation of moisture content under different measurement conditions;
● One injection can be converted into mg/L, ppm, mg/kg, %, % to reduce the number of measurements and reagent consumption, and the moisture content conversion unit can also be specified;
● Adjustment of samples volume, mass and density adjustment can be carried out during or after the test;
● 9-speed stirring speed adjustment; 9-speed electrolysis gain adjustment;
● Automatic detection and recording of measuring electrode open-circuit fault and short-circuit fault;
● Automatic storage of historical records with time stamps;
● Reserve RS232 and RS485 ports to communicate with the computer
Huazheng HZKF-2 Oil Karl Fischer Trace Moisture Analyser
The Huazheng HZKF-2 Oil Karl Fischer Trace Moisture Analyser is a laboratory testing instrument designed to determine trace amounts of water in transformer oil, insulating liquids, and other suitable liquid samples.
Using the Karl Fischer Coulometric Method, the instrument measures moisture content to support quality control, transformer maintenance, and laboratory testing.
Key Features:
- Karl Fischer coulometric moisture measurement technology.
- Designed for trace moisture analysis.
- Suitable for transformer oil and insulating liquid testing.
- Supports accurate moisture content determination.
- Digital display for convenient operation.
- Suitable for industrial and laboratory applications.
- Designed to meet applicable testing method requirements, including GB/T 7600 and related standards.
Applications:
- Transformer oil moisture analysis.
- Insulating oil quality testing.
- Electrical power industry laboratories.
- Transformer maintenance and testing.
- Industrial quality control.
- Engineering universities and polytechnic laboratories.